Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$title-short is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$category is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$updated is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$rights is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Characterization of Siemens Biograph 6 PET by Monte Carlo simulation
| Revista de Física Médica
Characterization of Siemens Biograph 6 PET by Monte Carlo simulation
Authors
Pedro Gallego Franco
Rocío García Marcos
Abstract
GAMOS simulation code based on Geant4 is a very powerful tool for the design and modeling optimization on Positron Emission Tomography (PET) systems. In order to obtain a proper image quality, it results to be extremely important determine the optimal activity which is going to be delivered. For this reason a study about the internal system parameters that affects image quality, such as scatter fraction (SF) and the count rate equivalent noise (NEC), has been carried out. The study involves the comparison of experimental measures on both parameters, with those obtained by Monte Carlo simulation of Siemens Pet Biograph 6 True Point with True V option. Based on simulation’s results, a paralizable dead-time model that adjusts, depending on the activity provided, the proper dead-time for scanner detectors. Also a study about the variation of this proper dead-time with the activity has been carried out.