Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$title-short is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$category is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$updated is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$rights is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Measurement of the dosimetric parameters for low monitor units in step-and-shoot IMRT delivered by Siemens Artiste linear accelerators
| Revista de Física Médica
Measurement of the dosimetric parameters for low monitor units in step-and-shoot IMRT delivered by Siemens Artiste linear accelerators
Authors
César Rodríguez Rodríguez
Alfonso López Fernández
Moisés Sáez Beltrán
Guadalupe Martín Martín
Leyre Alonso Iracheta
Abstract
Absorbed dose linearity and beam stability, both for low monitor units, are important factors for ensuring planned dose delivery in step-and-shoot IMRT. For Siemens Artiste linear accelerators, under IMRT stable irradiation conditions and for a single segment of 20 cm x 20 cm field size, the linearity of the absorbed dose with the monitor units, field flatness and symmetry have been measured for the range between 1 and 10 monitor units. We have found that absorbed dose linearity with monitor units is within 2% down to 2 monitor units and it is about 9% for 1 monitor unit. Flatness and symmetry values show variations within 1% down to 2 monitor units and increase by 9% for lower values. Using our monitor unit distribution per segment in IMRT we estimate that the uncertainty in absorbed dose for a whole treatment due to these factors is less than 1% (k= 3).