Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$title-short is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$category is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$updated is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: Creation of dynamic property Seboettg\CiteProc\Root\Info::$rights is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/citationStyleLanguage/lib/vendor/seboettg/citeproc-php/src/Root/Info.php on line 62
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Deprecated: htmlspecialchars(): Passing null to parameter #1 ($string) of type string is deprecated in /var/www/vhosts/revistadefisicamedica.es/httpdocs/plugins/generic/googleScholar/GoogleScholarPlugin.php on line 120
Verification of dose distributions of intensity-modulated radiotherapy beams using a portal imaging device
| Revista de Física Médica
Verification of dose distributions of intensity-modulated radiotherapy beams using a portal imaging device
Authors
JM Pérez Moreno
JP Fernández Letón
D Zucca Aparicio
J García Ruiz-Zorrilla
A Miñambres Moro
Abstract
We have developed a method for using a portal imaging device based on amorphous silicon (EPID) for the dosimetric verification of intensity modulated radiotherapy (IMRT) treatments using 6 MV beams. The images obtained using the imaging system are deconvolved with a kernel for radiation and scattering of light generated in the EPID. This kernel has an analytical form and has been experimentally determined. The fluence thus obtained is convolved with a dose deposition kernel, also modeled analytically in a empirical way. The result is an absorbed dose distribution in water at 5 cm depth. The difference between the measured dose using portal imaging device and ionization chamber is –0.3 ± 0.9 % in open fields, with a maximum deviation of 1.5% in a 20 cm × 20 cm field with 60° virtual wedge. The degree of agreement between dose distributions measured with the EPID and ionization chamber array is satisfactory, exceeding all cases evaluated 95% of points with γ < 1 using 3%, 3 mm criteria for gamma analysis.