Characterization of the spectral response of caesium iodide flat panel detectors in digital radiography

Trabajo presentado en el 3er Congreso Europeo de Física Médica (ECMP) y becado para su asistencia.

Authors

  • Aitor Fernández Iglesias Servicio de Radiofísica y Protección Radiológica. Hospital Universitario de Navarra - Nafarroako Unibertsitate Ospitalea. Pamplona
  • Santiago Miquelez Alonso Servicio de Radiofísica y Protección Radiológica. Hospital Universitario de Navarra - Nafarroako Unibertsitate Ospitalea. Pamplona
  • Fernando Caudepón Moreno Servicio de Radiofísica y Protección Radiológica. Hospital Universitario de Navarra - Nafarroako Unibertsitate Ospitalea. Pamplona

DOI:

https://doi.org/10.37004/sefm/2021.22.2.005

Keywords:

Exposure index, Digital Radiography, Optimization, Spectral response

Abstract

This work provides the characterization of the spectral response of caesium iodide flat panel detectors from several manufacturers. The analysis is done for the following model flat panels: 12 Flashpad from General Electric, 6 DRX Plus 4343C from Carestream, 4 CXDI-410 Wireless from Canon, 4 FDR D-EVO II from Fujifilm Corporation and 2 Pixium EZ from Trixell. The characterization is carried out by measuring Exposure Index – incident air kerma ratios for beams with different spectrum and results are provided for each flat panel model. Furthermore, it is proposed a methodology to verify the correct configuration of the anatomic menu.
Key words: Exposure Index, Digital Radiogra

References

American Association of Physicists in Medicine. An Exposure Indicator for Digital Radiography, Report of AAPM Task Group 116. College Park, MD: AAPM; 2009.

International Electrotechnical Commission (IEC), Medical Electrical Equipment: Exposure Index of Digital X-Ray Imaging Systems. Definitions and requirements for general radiography, Geneva, Switzerland, 2008.

Boone J.M., X-ray production, interaction and detection in diagnostic imaging. In: Beutel J., Kundel H.L., Van Metter R.L. (eds), Handbook of medical imaging, Vol1, Physics and Psychophysics., SPIE, Bellingham, 2000.