Design of a model for the estimation of the ambient equivalent dose received by the closest groups to the patients undergoing treatment of remains of thyroid Ca. with I-131

Authors

  • Juan Miguel Granado Olmedo
  • Cristina González Ruiz
  • Juan Miguel Becerro Morgado
  • Álvaro Soza Marañón

DOI:

https://doi.org/10.37004/sefm/2020.21.2.001

Keywords:

Effective elimination time, Ambient equivalent dose rate, Dose restriction, Post-therapy recommendations

Abstract

The aim is to make an adequate estimate of the ambient equivalent dose received by the groups closest to the patient, once the patient has the radiological and clinical discharge.

As a first step, a patient's daily life pattern with its closest environment has been modelled. A maximum dose rate of 40 μSv/h at 1 meter has been set to give the patient the radiological discharge.

Secondly, a fitting equation that gives us the evolution of the dose rate with distance has been formulated. How the function fits to the experimental points after measuring 45 patients at the distances between 0.4 and 2 meters was verified obtaining R2 ≥ 0.98 for 75.55% of the cases. Besides, a smaller error is made than using the equation of the Radiological Protection in the Healthcare Enviroment in 93.33% of cases.

When models are simulated, modes of the dose distributions do not exceed the dose restriction, namely, 3 mSv per treatment when partner is under 60 years old and 15 mSv when companion is over 60 years old.

Finally, an experimental elimination time is obtained, being this less than the given in the Forum document, reducing the mode of distributions between a half and one tenth.

References

Ramírez-Garzón YT, Ávila O, Medina LA, Gamboa-deBuen I, Rodríguez-Laguna A, Buenfil AE et al. Measurement of radiation exposure in relatives of thyroid cancer patients treated with (131)I. Health Phys 2014;107(5):410-416.

Criterios de alta de pacientes y medidas para la protección radiológica del público después de tratamientos metabólicos con I-131. Foro sobre protección radiológica en el medio sanitario. Consejo de Seguridad Nuclear, Sociedad Española de Protección Radiológica y Sociedad Española de Física Médica, 2011.

Kochovska MZ, Jokic VS, Majstoro V, Dugonjic S. Estimated dose to family members of patients treated with radioiodine. Radiat Prot Dosimetry 2017;174(2):250-254.

Al-jubeh W, Shaheen A, Zalloum O. Radioiodine I-131 for diagnosing and treatment of thyroid diseases. Comunicación personal 2012.

Uslu-Beşli L, Demir M, Yeyin N, Çavdar I. Radiation dose of caregivers could be reduced in thyroid carcinoma patients requiring high dose of radioactive iodine: A case report. Iran J Nucl Med 2016;24(2):144-146.

Gorgoso-Varela JJ, Rojo-Alboreca A. Use of Gumbel and Weibull functions to model extreme values of diameter distributions in forest stands. Ann For Sci 2014;71:744-750.

Downloads

Published

2020-11-23

Issue

Section

Scientific articles

How to Cite

Design of a model for the estimation of the ambient equivalent dose received by the closest groups to the patients undergoing treatment of remains of thyroid Ca. with I-131. (2020). Revista De Física Médica, 21(2), 11-19. https://doi.org/10.37004/sefm/2020.21.2.001

Similar Articles

21-30 of 237

You may also start an advanced similarity search for this article.