Image dosimetry for Y90 hepatic radioembolization: impact of PET spatial resolution.

Trabajo presentado en el 3er Congreso Europeo de Física Médica (ECMP) y becado para su asistencia.

Authors

  • Nuria Carrasco Vela Hospital Universitario Dr. Peset. Valencia
  • Natalia Tejedor Aguilar Hospital Universitario y Politécnico La Fe. Valencia
  • Vicente Giménez Gómez Universidad de Valencia - Instituto de Física Corpuscular (IFIC). Valencia
  • Irene Torres Espallardo Hospital Universitario y Politécnico La Fe. Valencia

DOI:

https://doi.org/10.37004/sefm/2021.22.2.004

Keywords:

Hepatic radioembolization, image-based dosimetry, PET spatial resolution

Abstract

PET image plays a key role in quantitative image-based  dosimetry for hepatic Y90 radioembolization. Nevertheless,  given the limited scanner spatial resolution, the real activity  distribution is blurred. It is usually argued that the blurring  introduced by the PET is larger than the one due to the  convolution kernel (VSV method) so that Local Deposition  Method (LDM) provides sufficiently precise results. In the  present work we have compared dosimetric results from LDM,  VSV and Monte Carlo on synthetic PET images which have been  blurred in order to simulate PET spatial resolution.

References

Garin E, Tselikas L, Guiu B, et al. Personalised versus standard dosimetry approach of selective internal radiation therapy in patients with locally advanced hepatocellular carcinoma (DOSISPHERE-01): a randomised, multicentre, open-label phase 2 trial. The Lancet Gastroenterology & Hepatology 2021 Jan; 6:17{29. doi: 10.1016/s2468-1253(20)30290-9. Available from: https://doi.org/10.1016/s2468-1253(20)30290-9

Ho S, Lau WY, Leung TWT, Chan M, Ngar YK, Johnson PJ, and Li AKC. Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumours. European Journal of Nuclear Medicine 1996; 23:947{52. doi: 10.1007/bf01084369. Available from: https://doi.org/10.1007/bf01084369

Bolch W, Bouchet L, Robertson J, Wessels B, Siegel J, Howell R, Erdi A, Aydogan B, Costes S, Watson E, Brill A, Charkes N, Fisher D, Hays M, and Thomas S. MIRD pamphlet No. 17: the dosimetry of nonuniform activity distributions{radionuclide S values at the voxel level. Medical Internal Radiation Dose Committee. Journal of nuclear medicine : ocial publication, Society of Nuclear Medicine 1999; 40:11S{36S. Available

from: http://europepmc.org/abstract/MED/9935083

Pasciak AS, Bourgeois AC, and Bradley YC. A Comparison of Techniques for 90Y PET/CT Image-Based Dosimetry Following Radioembolization with Resin Microspheres. Frontiers in Oncology 2014 May; 4. doi: 10.3389/fonc.2014.00121. Available from: https://doi.org/10.3389/fonc.2014. 00121

Willowson KP, Tapner M, and Bailey DL. A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres. European Journal of Nuclear Medicine and Molecular Imaging 2015 May; 42:1202{22. doi: 10.1007/s00259-015-3059-9. Available from: https://doi.org/10.1007/s00259-015-3059-9

Werner MK, Parker JA, Kolodny GM, English JR, and Palmer MR. Respiratory Gating Enhances Imaging of Pulmonary Nodules and measurement of Tracer Uptake in FDG PET/CT. American Journal of Roentgenology 2009 Dec; 193:1640{5. doi: 10.2214/ajr.09.2516. Available from: https://doi. org/10.2214/ajr.09.2516

Elmbt L van, Vandenberghe S, Walrand S, Pauwels S, and Jamar F. Comparison of yttrium-90 quantitative imaging by TOF and non-TOF PET in a phantom of liver selective internal radiotherapy. Physics in Medicine and Biology 2011 Oct; 56:6759{77. doi: 10.1088/0031-9155/56/21/001. Available from: https://doi.org/10.1088/0031-9155/56/21/001

Bagni O, D'Arienzo M, Chiaramida P, Chiacchiararelli L, Cannas P, D'Agostini A, Cianni R, Salvatori R, and Scopinaro F. 90Y-PET for the assessment of microsphere biodistribution after selective internal radiotherapy. Nuclear Medicine Communications 2012 Feb; 33:198{204. doi: 10.1097/mnm.0b013e32834dfa58. Available from: https://doi.org/10.1097/mnm.0b013e32834dfa58

Delso G, Fürst S, Jakoby B, Ladebeck R, Ganter C, Nekolla SG, Schwaiger M, and Ziegler SI. Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner. Journal of Nuclear Medicine 2011 Nov; 52:1914-22. doi: 10.2967/jnumed.111.092726. Available from: https://doi.org/10.2967/jnumed.111.092726

Downloads

Published

2021-11-05

Issue

Section

Trabajos becados por la SEFM

How to Cite

Image dosimetry for Y90 hepatic radioembolization: impact of PET spatial resolution.: Trabajo presentado en el 3er Congreso Europeo de Física Médica (ECMP) y becado para su asistencia. (2021). Revista De Física Médica, 22(2), 43-48. https://doi.org/10.37004/sefm/2021.22.2.004
Bookmark and Share

Similar Articles

41-50 of 92

You may also start an advanced similarity search for this article.